Fluke Electronics® 4691215 - Insulation 13-Function Data Logging Multimeter

0 reviews|Item # mpn4737625455|Similar Products
$971.94
OUT OF STOCK - Unavailable until further notice
Authorized Dealer
Have a Question? Ask a Specialist
888.453.5148Live Chat

Product Details

Insulation 13-Function Data Logging Multimeter by Fluke Electronics®. Keep yourself safe. Find hidden problems faster. Put the paperwork down. Fluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelesly communicate your work quickly and easily - all at a safe distance.

Specifications

AC Voltage Range: 600mV (Accuracy: +/- 1% + 3), (Resolution: 0.1mV)
6V (Accuracy: +/- 2% + 3), (Resolution: 0.1mV)
60V (Accuracy: +/- 1% + 3), (Resolution: 0.1V)
600V (Accuracy: +/- 2% + 3), (Resolution: 0.1V)
1000V (Accuracy: +/- 2% + 3), (Resolution: 1V)
Low-Pas Filter Voltage Range: 600mV (Accuracy: +/- 1% + 3), (Resolution: 0.1mV)
DC Voltage Range: 6V (Accuracy: +/- 0.09% + 2), (Resolution: 0.001V)
60V (Accuracy: +/- 0.09% + 2), (Resolution: 0.01V)
600V (Accuracy: +/- 0.09% + 2), (Resolution: 0.1V)
1000V (Accuracy: +/-0.09% + 2), (Resolution: 1V)
Input Impedance: 10 meg Ohms (nominal), < 100 pF
Normal Mode Rejection Ratio: > 60 dB @ 50 Hz or 60 Hz
Common Mode Rejection Ratio: > 120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
Accuracies: apply to +/- 100% of range
DC MilliVoltage Range: 600mV (Resolution: 0.1mV, Accuracy: +/- 0.1% + 1)
AC Current Range: 400mA (Resolution: 0.1mA, Accuracy: +/- 1.5% + 2)
Burden Voltage (Typical) 2mV/mA Range: 60mA (Resolution: 0.01mA, Accuracy: +/- 1.5% + 2)
DC Current Range: 400mA (Resolution: 0.1mA, Accuracy: +/- 0.2% + 2)
Burden Voltage (Typical): 2mV/mA Range: 60mA (Resolution: 0.01mA, Accuracy: 0.2% + 2)
Burden Voltage (Typical) 2mV/mA Overload: 600mA for 2 minutes maximum
Fuse protection for mA input: 0.44mA, 1000V, IR 10 kA
AC conversion: Inputs are ac-coupled and calibrated to the rms value of sine wave input
Resistance Range: 600 Ohms (Accuracy: +/- 0.9% + 2, Resolution: 0.1 Ohms)
6 kOhms (Accuracy: +/- 0.9% + 2, Resolution: 0.001 kOhms)
60 kOhms (Accuracy: +/- 0.9% + 2, Resolution: 0.01 kOhms)
600 kOhms (Accuracy: +/- 0.9% + 2, Resolution: 0.1 kOhms)
6 meg Ohms (Accuracy: +/- 0.9% + 2, Resolution: 0.001 meg Ohms)
50 meg Ohms (Accuracy: +/- 1.5% + 3, Resolution: 0.01 meg Ohms)
Overload Protection: 1000V RMS or DC
Open Circuit Test Voltage: < 8V DC
Short Circuit Current: < 1.1mA
Diode Test Indication: Display voltage drop: 0.6V at 1.0mA nominal test Current (Accuracy: +/- 2% + 3)
Continuity Test Indication: Continuous audible tone for testresistance below 25 Ohms and off above 100 Ohms
Maximum Reading: 1000 Ohms
Open Circuit Voltage: < 8V
Short Circuit Current: 1.0mA typical
Overload Protection: 1000V RMS
Response Time: > 1m sec
Frequency Range: 99.99 Hz (Accuracy: +/- 0.1% + 1, Resolution: 0.01 Hz)
999.9 Hz (Accuracy: +/- 0.1% + 1, Resolution: 0.1 Hz)
9.999 kHz (Accuracy: +/- 0.1% + 1, Resolution: 0.001 kHz)
99.99 kHz (Accuracy: +/- 0.1% + 1, Resolution: 0.01 kHz)
Capacitance Range: 1000 nF (Accuracy: +/- 1.2% + 2, Resolution: 1 nF)
10 uF (Accuracy: +/- 1.2% + 2, Resolution: 0.01 uF)
100 uF (Accuracy: +/- 1.2% +/- 90 counts, Resolution: 0.1 uF)
9999 uF (Accuracy: +/- 1.2% +/- 90 counts, Resolution: 1 F)
Temperature Range: -40°C to 537°C (-40°F to 998°F)
Temperature Accuracy: +/- 1% + 10 counts (+/- 1% + 18 counts)
Temperature Resolution: 0.1°C ( 0.1°F)
Insulation Specifications:
Measurement Range: 0.01 meg Ohms to 2 gOhms
Test Voltages: 50V, 100V, 250V, 500V, 1000V
Test Voltage Accuracy: +20%, -0%
Short-Circuit Test Current: 1mA nominal
Auto Discharge: Discharge time < 0.5 second for C = 1 UF or les
Live Circuit Detection: Inhibit test if terminal voltage > 30 V prior to initialization of test
Max. Capacitive Load: Operable with up to 1 uF load
Output Voltage: 50V
Display Range: 0.01 to 6.00 meg Ohms
Resolution: 0.01 meg Ohms
Test Current: 1mA @ 50 kOhms
Resistance accuracy: +/- 3% + 5 counts
Display Range: 6.0 to 50.0 meg Ohms
Resolution: 0.1 meg Ohms
Resistance Accuracy: +/- 3% + 5 counts
100V:
Test Current: 1 mA @ 100 kOhms
Display Range: 6.0 to 60.0 meg Ohms
Test Current: 1mA @ 100 kOhms
Display range: 60 to 100 meg Ohms
Resolution: 1 meg Ohms
250V: Display Range: 0.1 to 60.0 meg Ohms
Test Current: 1mA @ 250 kOhms
Resistance Accuracy: +/- 1.5% + 5 counts
Display Range: 60 to 250 meg Ohms
500V Display Range: 0.1 to 60.0 meg Ohms
Test Current: 1mA @ 500 kOhms
Display Range: 60 to 500 meg Ohms
Test Current: 1 mA @ 500 kOhms
1000V Display Range: 0.1 to 60.0 meg Ohms
Test Current: 1 mA @ 1 meg Ohms
Display Range: 60 to 600 meg Ohms
Display Range: 0.6 to 2.0 g Ohms
Resolution: 100 meg Ohms
Test Current: 1mA @ 1 meg Ohms
Resistance Accuracy: +/- 10% + 3 counts
Storage Temperature: -40°C to 60°C (-40°F to 140°F)
Operating Temperature: -20°C to 55°C (-4°F to 131°F)
Temperature Coefficient: 0.05 x (specified accuracy) per °C for temperatures < 18°C or > 28°C ( < 64°F or > 82°F)
Relative Humidity: 0% to 95% @ 10°C to 30°C (50°F to 86°F), 0% to 75% @ 30°C to 40°C (86°F to 104°F), 0% to 40% @ 40°C to 55°C (104°F to 131°F)
Vibration: Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Clas 2 instrument
Radio Frequency Communication: 2.4 GHz ISM Band
Radio Frequency Certification: FCC: T68-FBLE, IC: 6627A-FBLE
Batteries : 4 Pieces AA batteries (NEDA 15A or IEC LR6)
Battery Life: Meter use 1000 hours
Safety Rating: CATIV 600V, CATIII 1000V
Dimensions: 5.0cm x 10cm x 20.3cm (1.97" x 3.94" x 8")
Weight: 550g (1.2 lbs)
Operating Altitude: 2,000m
Storage Altitude: 12,000m
Over-Range Capability: 110% of range except for capacitance which is 100%
Frequency Overload Protection: < 107V Hz
Fuse protection for mA input: 0.44A, 1000V, IR 10 kA

Includes

  • Insulation Multimeter
  • Remote Probe
  • Test Leads
  • Alligator Clips
  • K-type Thermocouple
  • Hard Case
  • User Documentation

Features

  • Safety first. Keep yourself out of harm's way by monitoring your test measurements remotely
  • Prove your job is done right by quickly seeing and sharing measurement results wirelesly with your smartphone
  • Quickly find problems by saving and comparing measurements over time on a wireles device
  • Three Years Warranty

Add diagnostics with Fluke Connect

The Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, including:

  • Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely
  • Prove your job is done right by quickly seeing and sharing measurement results wirelesly with your smartphone
  • Quickly find problems by saving and comparing measurements over time on a wireles device
  • PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster
  • Memory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time
  • Temperature compensation to establish accurate baselines and relevant historical comparisons
  • Historical tracking and trending of asets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Asets (sold separately)
  • Provides memory storage through Fluke Connect Measurements to eliminate the need to write down results
  • Includes live circuit detection to prevent insulation test if voltage >30 V is detected
  • Provides automated temperature compensation to establish accurate baselines
  • Supports historical tracking and aset trending of asets to identify degradation over time with Fluke Connect® Asets (sold separately)
  • Incorporates VFD low-pas filter for accurate variable frequency motor drive measurements
  • Includes auto-discharge of capacitive voltage for added user protection
  • Measures ac/dc voltage, dc millivolts, ac/dc milliamps, resistance, and continuity
  • Includes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading
  • Automatically powers off to save battery power
  • Comes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.

Fluke Electronics® Corporation is the world leader in the manufacture, distribution and service of electronic test tools and software. Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.

Part Number:
4691215
UPC:
095969796620
Alternate MPN:
1587 FC

Reviews

(0)
Only authorized customers can leave a review on our website. We would love to know what you like or dislike about the product. Share your opinion on product quality, appearance, installation, and other characteristics.
Fluke Electronics® 4691215 - Insulation 13-Function Data Logging Multimeter
/0

Questions and Answers

(0)
If you have any questions about this product, please don't hesitate to ask us. We will be happy to help you!
TOOLSiD FacebookTOOLSiD TwitterTOOLSiD YouTube ChannelTOOLSiD PinterestTOOLSiD Instagram
All manufacturer names, symbols, and descriptions, used in our images and text are used solely for identification purposes only. It is neither inferred nor implied that any item sold by TOOLSiD.com is a product authorized by or in any way connected with any manufacturers displayed on this page.
CUSTOMER SERVICE
INFORMATION
CONTACTS